Accepting Pre-Orders Now
FDA Cleared for professional and other healthcare use under a CLIA Certificate of Waiver only.
Discount Bulk Pricing Available - Contact Us!
The Rapid Response™ Drug Screen Panel is a CLIA Waived, one-step rapid test that detects multiple drugs and metabolites in urine and is now enhanced with the addition of a fentanyl test strip. With the rising prevalence of fentanyl in the drug supply, incorporating fentanyl testing into our CLIA Waived test panels is a critical feature, providing you with accurate and rapid results that meet your testing needs.
The Rapid Response™ Drug Screen Panel can be a single drug test panel or used for any combination of the listed analytes below:
Available Parameters
Drug | Cut-off (ng/mL) |
Amphetamine (AMP) | 500 |
Buprenorphine (BUP) | 10 |
Secobarbital (BAR) | 300 |
Oxazepam (BZO) | 300 |
Cocaine (COC) | 150 |
Methamphetamine (MET) | 500 |
Methylenedioxymethamphetamine (MDMA) | 500 |
Morphine (MOP/OPI) | 300 |
Methadone (MTD) | 300 |
Oxycodone/Oxymorphone (OXY) | 100 |
Phencyclidine (PCP) | 25 |
Marijuana (THC) | 50 |
Fentanyl (FYL) | 1 |
Demonstration

RapidReader App

Lateral Flow Scanner
Accepting Pre-Orders Now
FDA Cleared for professional and other healthcare use under a CLIA Certificate of Waiver only.
Discount Bulk Pricing Available - Contact Us!
The Rapid Response™ Drug Screen Panel is a CLIA Waived, one-step rapid test that detects multiple drugs and metabolites in urine and is now enhanced with the addition of a fentanyl test strip. With the rising prevalence of fentanyl in the drug supply, incorporating fentanyl testing into our CLIA Waived test panels is a critical feature, providing you with accurate and rapid results that meet your testing needs.
The Rapid Response™ Drug Screen Panel can be a single drug test panel or used for any combination of the listed analytes below:
Available Parameters
Drug | Cut-off (ng/mL) |
Amphetamine (AMP) | 500 |
Buprenorphine (BUP) | 10 |
Secobarbital (BAR) | 300 |
Oxazepam (BZO) | 300 |
Cocaine (COC) | 150 |
Methamphetamine (MET) | 500 |
Methylenedioxymethamphetamine (MDMA) | 500 |
Morphine (MOP/OPI) | 300 |
Methadone (MTD) | 300 |
Oxycodone/Oxymorphone (OXY) | 100 |
Phencyclidine (PCP) | 25 |
Marijuana (THC) | 50 |
Fentanyl (FYL) | 1 |
Demonstration
CLIA Waived drug screening cup with Fentanyl
Detects Fentanyl with a low cut-off level of 1ng/mL
Results in 5 minutes
The Rapid Response™ Drug Screen Panel features a highly sensitive fentanyl test strip with a low cut-off level of 1ng/mL. This test panel is an ideal choice for professionals looking for precise and reliable drug screening solution. The test can be a single drug test panel or used for any combinations of the listed analytes below:
Drug | Cut-off (ng/mL) |
Amphetamine (AMP) | 500 |
Buprenorphine (BUP) | 10 |
Secobarbital (BAR) | 300 |
Oxazepam (BZO) | 300 |
Cocaine (COC) | 150 |
Methamphetamine (MET) | 500 |
Methylenedioxymethamphetamine (MDMA) | 500 |
Morphine (MOP/OPI) | 300 |
Methadone (MTD) | 300 |
Oxycodone (OXY) | 100 |
Phencyclidine (PCP) | 25 |
Nortriptyline (TCA) | 1000 |
Marijuana (THC) | 50 |
Fentanyl (FYL) | 1 |
The Rapid Response™ Drug Screen Panel is available with an option of built-in Specimen Validity / Adulteration Test Strips. The following parameters are available:
- Oxidants / Pyridinium Chlorochromate
- Specific Gravity
- pH
- Nitrite
- Glutaraldehyde
- Creatinine

Interpretation of test results are: positive (one line), negative (two lines), invalid (no lines or no control line); or the comparison of reaction pad color to the corresponding color blocks for the adulteration strips.
Please refer to the product insert for more details.
The following list of drug parameters can be detected. Any combination of the below drug parameters and cut offs are CLIA Waived.
Drug | Cut-off (ng/mL) |
Amphetamine (AMP) | 500 |
Buprenorphine (BUP) | 10 |
Secobarbital (BAR) | 300 |
Oxazepam (BZO) | 300 |
Cocaine (COC) | 150 |
Methamphetamine (MET) | 500 |
Methylenedioxymethamphetamine (MDMA) | 500 |
Morphine (MOP/OPI) | 300 |
Methadone (MTD) | 300 |
Oxycodone/Oxymorphone (OXY) | 100 |
Phencyclidine (PCP) | 25 |
Nortriptyline (TCA) | 1000 |
Marijuana (THC) | 50 |
Fentanyl (FYL) | 1 |
The Rapid Response™ Drug Screen Panel is compatabile with the Rapid Response™ Lateral Flow Scanner, a revolutionary workflow solution redefining the approach to drug screen reporting in staffing agencies, treatment centers, and laboratories. The Lateral Flow Scanner captures results of up to 5 test panels, allows the operator to confirm the results and then transmits the data directly to your organizations EMR, ATS or LIS with the click of a button.
- Please note that certain products may only be available in specific regions; kindly consult with a sales representative for further information regarding product availability.
- The information provided on this website is for educational purposes only and should not be construed as medical advice. Always consult with a qualified healthcare professional regarding any medical concerns or conditions.
- Our products are intended for use as specified in the product documentation. It is important to carefully read and follow all instructions provided with the product.